With easy to follow instructions. 256K views 8 years ago If your Vaillant water heater is stuck on F.28 or F.29, you have no hot water and the burner is not even starting, you need to reset the error code. This error code is triggered by fan failure, a blocked or leaky flue pipe, or a communication failure between the fan and the PCB. It is also possible that the bypass valve is not set correctly or that there is blockage in the system. It is considered that the optimum home temperature is between 18-21C. If i put it in SFH mode (- and +) i can get it to pump heat into the rads for around 10/15 minutes thus . Manage Settings The fact that you have just had a new pump is a coincidence as the service interval is determined by how many hours the boiler has been running since the last service. (Consider the environment and only print this manual if it is really necessary), Vaillant ecoTEC pro 28 Central Heating Boiler. This switch should be. +49 21 91 180 Fax +49 21 91 182810 info@vaillant.de www.vaillant.de. If the lockout persists or reoccurs, following three separate resets, then seek support from your approved Engineer. Sorry to go back to an old thread here. It is essential to ensure that you consult the instruction manual for your specific boiler before carrying out any troubleshooting and, if in doubt, consult the assistance of a Gas Safe Registered engineer. for F.28. This would usually indicate an issue with the fan. Most common Reason. The value will. A Bailey Plumbing & Heating Ltd, Company number 9680455, registered in England and Wales. I know when its happened because the hot taps run cold. Page 9: Operating Concept I have just moved into my new property that has a Vaillant ecoTEC pro 28 installed, it fires ok, hot water and heating, however, it is fitted with a Salas wireless thermostat, I have programmed it so that the heating comes on as we need it, however when I switch the boiler to auto on the from panel of the boiler the red light just flashes and the heating does not come on, even switching the wireless thermostat to hand and raising the temperature. with a sparkle finish.https://youtu.be/bdjcBQo7cogHow to clean the MagnaClean Professional 1https://youtu.be/dwbFx0wG3lkHow to clean the MagnaClean Professional 2https://youtu.be/8-dqkTsfv6MMagnaClean Professional 2, How to add Inhibitor.https://youtu.be/8-dqkTsfv6MTOOLS, Einhell Classic TC VC1930S Wet \u0026 Dry Vacuum Review.https://youtu.be/y4hY7zkAYuQThe Gas Safe Register.https://www.gassaferegister.co.ukIf you want to support me further then please leave a Donation in myTOOL BOX FUND.https://www.paypal.com/donate/?cmd=_s-xclick\u0026hosted_button_id=AQE6ZCCN5VMLAChapters0:00 Vaillant ecotec Pro Combination Boiler Operation / Introduction.1:35 Vaillant ecotec Pro Combination Boiler Operation.1:46 Vaillant ecotec Pro Combination Boiler Clock Options.2:47 Vaillant ecotec Pro Combination Boiler Turn ON and OFF.3:12 Vaillant ecotec Pro Combination Boiler Adjusting Hot Water Temperature.5:39 Vaillant ecotec Pro Combination Boiler Comfort / Warm Start / Pre-Heat Setting.7:41 Vaillant ecotec Pro Combination Boiler Heating Temperature.9:36Vaillant ecotec Pro Combination Boiler Pressure Gauge.10:54 Vaillant ecotec Pro Combination Boiler Reset.11:57 Vaillant ecotec Pro Combination Boiler operating in actionIf you want to support me further then please leave a Donation in myTOOL BOX FUND.https://www.paypal.com/donate/?cmd=_s-xclick\u0026hosted_button_id=AQE6ZCCN5VMLAI've been a gas engineer for over 20 The aim of my channel is to help you with your central heating and plumbing systems. How Do I Reset My Vaillant Boiler? Your heating should now operate. Normal service is resumed by pressing the reset button. At this stage, your boiler will lock out. The thermostat can be set to intelligent control, which provides greater efficiency and a more comfortable room temperature. 10 years. Locate the boiler's reset button The button will feature a flame, flashing light, or a cross and should be clearly labelled RESET in your instruction manual. Vaillant Eco Tec Pro 28 The engineer will have made a judgement call on the insulation that probably didn't factor in you f-ing about with it! F75 is a very common fault code on Vaillant ecoTEC boilers and appears when the boiler is unable to detect sufficient pressure as the pump is in operation. F22 Fault.https://youtu.be/G1qADHtsquMVideo: How to Balance your Heating System. check that the room thermostat is calling for heat. 3. try to find local (NR30) Vaillant expert for repair. Resetting a Vaillant boiler is relatively straightforward. Should this occur, take a look through the instruction manual provided by the manufacturer for instructions on adjusting the timer settings. You must log in or register to reply here. The gas is probably being prevented from getting to the boiler because of a gas valve problem. Wait for the boiler to reset this may take several minutes. "postalCode": "B17 9RA", left ON continuously to operate the boiler. A boiler's computer will display what it thinks is the most relevant fault code for the issue. If it is around this but the F22 error is showing, the issue is likely to be with the sensor itself. Display 4. What is causing this? How can I stop this? Is your question not listed? Your thermostat is designed to control the boiler heating system, ensuring the propertys temperature is maintained to your preference. From the general operation and maintenance to the more advanced fault finding, installation and repairing of your systems.Please dont forget to SUBSCIBE and click the bell for notification of my new videos. Page 1 How to use your Vaillant ecoTEC pro combination boiler ecoTEC operating controls 1. The ignition for heating mode is activated. 3. try to find local (NR30) Vaillant expert for repair. The 28CDi compact is also a great fit for standard-size kitchen cupboards. Below you can view and download the PDF manual for free. - Gas Boiler Replacement The radiator temperature control (2) sets the, Check that the remote programmer is in an on, setting (see separate programmer instructions) and. Boiler Leaks Possible fault codes: F22 Boiler leaks can happen for various reasons, such as corroded or faulty components, broken seals, or excessive pressure. The, temperature of the hot water can be controlled by, the control knob (1). Terms \u0026 conditions apply. boiler slowly over 48 hr losing pressure check for leaks on heating circuit none , no leaks from boiler itself any ideas? There are also frequently asked questions, a product rating and feedback from users to enable you to optimally use your product. Air bubbles escaping, radiators bleeding air, very very small leak. If you have a new boiler, you might notice that it has a mechanical timer. View the manual for the Vaillant EcoTEC pro 28 here, for free. It consists of a display Chimney sweep mode (for chimney sweeps only) showing symbols and 5 operation buttons. And, as boiler's display fault codes and lockout as a safety feature, it's not advisable to reset a boiler until a Gas Safe engineer has diagnosed and fixed the problem. Get yearly reminders 30 days before your service due date. Most people find that the ideal room temperature is between 19 and 22 degrees Celsius. Need a manual for your Vaillant ecoTEC pro 28 Central Heating Boiler? The ecoTEC Pro 28 kW Combi Gas Boiler from Vaillant is a condensing unit with an efficiency rating of 94%. If you happen to have one of the Vaillant ecoTEC PRO or PLUS combination or system boilers, there is a very good chance you may experience the F27 fault code at some point. Size: 4.28 MB Table of Contents . Filling the Heating System in Ecotec Pro Combination Boilers and Ecotec Plus System Boilers. vaillant ecotec pro 28 printed circuit board with connectors disconnected With this boiler, the circuit board would put power onto the fan which would spin for a second and then the screen would go blank for a period.. Do you have a question about the Vaillant EcoTEC pro 28 or do you need help? #1. - Boiler Central Heating Controls, - Gas Safety Inspections Is your product defective and the manual offers no solution? We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. If you speak to Vaillant technical support they would suggest to disconnect the fan and see if the appliance goes to the F.32 . we have water coming out of the boiler,what could cause this? Image 2: Vaillant Gas valve with stepper motor. I will go through the boiler step by step showing you how to adjust your hot water temperature and the most efficient temperature to set it at.Your central heating temperature and the most efficient temperature to set it at.How to Re-set your Vaillant ecotec Boiler.How to turn ON and OFF the \"Comfort setting / hot water Preheat\" on this Boiler!!! To reset, simply press down and hold for one second. The old but gold way to fix boiler clock problems is by resetting the controls. No 3 Reset Button Vaillant Ecotec New F28 , No 3 Reset Button. A Vaillant boiler that is failing to power up is less than ideal, however modern devices are set to enter lockout when there is a problem or a potential safety risk. If the spanner is showing due to maintenance interval, you can go and reset the maintenance timer. I have links to my other videos.Links To Other Help Videos.How to refill you boiler.Coming soonHow to operate you boiler and all the best setting.Coming soonHow to replace a radiator valve EXTENDED version.https://youtu.be/VkLIRP2ZVqwHow to remove a radiator for decorating.https://youtu.be/Mf-c1aRyJa0How to refit a radiator after decorating.https://youtu.be/kH0Etr2TCGIHow to replace a radiator valve.https://youtu.be/XQlp917EQDIHow repair leaking radiator blanking plug.https://youtu.be/lh8Q5QbsYlYHow to add inhibitor into your, with out draining the system.https://youtu.be/PWIlbuYQSpcBoiler continuously losing pressure.https://youtu.be/AQBkruetrTcHow to flush out your radiator.https://youtu.be/bmc4mzBbVT0The Gas Safe Register.https://www.gassaferegister.co.ukIf you want to support me further then please leave a Donation in myTOOL BOX FUND.https://www.paypal.com/donate/?cmd=_s-xclick\u0026hosted_button_id=AQE6ZCCN5VMLA Please dont forget to subscribe for more help videos.I've been a gas engineer for over 20 The aim of my channel is to help you with your central heating and plumbing systems. Not open for further replies. The efficiency rating of a boiler is how much energy is lost during the process of producing heat and hot water. Fixing the F75 fault Fixing the F75 error code needs a Gas Safe registered engineer to find out whether the issue lies with the pump or pressure sensor. Vaillant Protection Kit.https://youtu.be/P8vim3NfHEMHow to top up Vaillant ecotec Pro Combination Boiler. When the boiler fails, a fault, code is displayed and held in the appliance, To turn the boiler off completely turn the main, the pressure reading on the gauge (6) is below, 0.7 bar or in the event of any other problems, Gas fired wall hung high efficiency boiler (32 pages), Gas-fired wall-hung high-efficiency boiler (12 pages), Gas-fired wall hung high efficiency boiler (36 pages), Flue pipe, concentric o 110/160 (32 pages), Gas-fired wall-hung high efficiency boiler (36 pages), Manual will be automatically added to "My Manuals", Boiler Vaillant ecoTEC plus Series Instructions For Use Manual, Boiler Vaillant ecoTEC pro Operating Instructions Manual, Boiler Vaillant ecoTEC pro Installation And Maintenance Instructions Manual, Boiler Vaillant ecoTEC plus Operating Instructions Manual, Boiler Vaillant ecoTEC plus Installation Manual, Boiler Vaillant ecoTEC plus Installation And Maintenance Instructions Manual, Boiler Vaillant ecoTEC plus Series Operating Instructions Manual, Boiler Vaillant ecotec plus Installation And Maintenance Instructions Manual. All you need to do is press the reset button which is typically located close to the boiler's display and hold it for 3-5 seconds. Ensure the electrical supply to the boiler is turned, on. There is probably air in the heating system. The boiler will attempt to light three times; if it cannot detect a flame, the F28 code appears, meaning there is a problem. 2..call Vaillant for 285 fixed price repair. The question is 1. do nothing but keep pressing reset. "addressLocality": "Birmingham", An example of data being processed may be a unique identifier stored in a cookie. The, boiler should now operate. View online or download Vaillant ecoTEC plus 824 Instructions For Installation And Servicing, Installation And Maintenance Instructions Manual, Installation And Maintenance Manual, Instructions For Use Manual . Do I Need to Reset my Vaillant Boiler After An F72? Turn the valves. Is an F23 the Same As the Boiler Overheating? #1 - Check Your Boiler's Water Pressure Sensor The first thing you need to do if you get an F22 error on your Vaillant boiler is to check your boiler's water pressure sensor. A Bailey Plumbing & Heating Ltd acts as a credit broker and not a lender and do not receive a fee for the introduction. Product Description. Ask your question here Kings Norton Con- nect the VR 65 or VR61 Control Centre as described in its enclosed manual. The temperature range can be, adjusted from a minimum of 35C to a maximum of, approximately 60C. Once you have held down the button for three seconds, you should be able to identify whether your boiler has been reset as changes will occur on the display. Confirm the thermostat temperature and increase it; if that was the issue, then the boiler should begin to fire up. You have to use the manual to set and change the time correctly. Boiler will try to. I fully bleed, then run the purge program, then bleed again and re-pressurise to 1.3. Brand new gas boiler installations, Birmingham. - 9.9% Finance Option Boiler "ON & OFF" switch 6. See the website or talk to one of our sales team for full details: https://www.swaleheating.com/Check out our social media pages for regular updates:Facebook: https://www.facebook.com/SwaleHeating/Twitter: https://twitter.com/SwaleHeating If the weather is extremely cold make sure your condensate pipe has not frozen or got blocked. This video focuses on the Vaillant ecotech pro28 boiler. This manual is available in the following languages: English. Go to a Repair Caf for free repair services. be briefly displayed on the boiler display (3). #1 Hi folks.I have a Vaillant ecotec pro 28.Central heating is working and hot water is too but an egg timer symbol has appeared that was never there before?No settings have been changed.Does anyone know what this means please? What dial are you turning, and does she have a sister? Page 1 Installation and maintenance instructions ecoTEC pro VUW ..6/5-3 GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. F.26 Fault Code Repair. "address": { }, Copyright 2023 | A Bailey Plumbing & Heating Ltd | Registered in England & Wales | Company Registration No 9680455 | VAT Reg No 244 1431 39. The code displays on the front of the boiler and overrides any other function of the boiler. Once the pressure is reached shut the valve and turn the boiler off and back on. Remember that this. } I have an EcoTec Pro 28, it's producing hot water just fine but no central heating. Are you satisfied with this Vaillant product? The engineer who dealt with the issue will usually do this for you. You can find more information on resolving issues by looking at the fault description or by typing in the fault code in the question bar above and clicking "ASK". If your Vaillant boiler locks out, you can use our handy video to show you how to reset your boiler and get it operating at its maximum potential again.With up to a 10-years manufacturer's warranty available and a 1-year maintenance contract with all new central heating installations, theres never been a better time to make the move to a new A-rated boiler with Swale Heating! Resetting your ecoTEC boiler Resetting the boiler If the burner fails to ignite after five attempts, the boiler will not operate and switches to "Fault". got f75 fault reading and the pressure is at 4,6. If the boiler shuts off, after the third attempt, then please consult your, Service Provider. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. We also have an comprehensive troubleshooting guide which is easy to use. If you are having issues with the thermostat check the thermostat is wireless connected to the hive hub? Credit is provided by Novuna Personal Finance, a trading style of Mitsubishi HC Capital UK PLC authorised and regulated by Financial Conduct Authority. This works perfectly for your vaillant boiler Eco Tech Pro 28. The pump prerun for heating mode is activated. Has your Vaillant boiler stopped working and the display now say \"F28 or F29\" In this video I show you how to reset your boiler.Also what might be causing the problem.What to do before you call an Gas Engineer.And why your boiler has to be reset.Plus Photos from the instruction manuals of the Fault code list.If you want to support me further then please leave a Donation in myTOOL BOX FUND.https://www.paypal.com/donate/?cmd=_s-xclick\u0026hosted_button_id=AQE6ZCCN5VMLAMy sitehttp://www.markballard-ltd.com/The aim of my videos are to help you, whether you are a complete beginner or if you have experience in this work. Fault.Https: //youtu.be/G1qADHtsquMVideo: How to use your product and 22 degrees Celsius 5... Resets, then the boiler because of a boiler & quot ; on amp! Balance your Heating System no leaks from boiler itself any ideas +49 21 91 180 Fax +49 91..., it & # x27 ; s computer will display what it thinks is the most relevant fault for... Really necessary ), Vaillant ecoTEC pro Combination Boilers and ecoTEC Plus System Boilers unit with an rating! You must log in or register to reply here display what it thinks is most! Temperature is between 19 and 22 degrees Celsius f22 error is showing due to maintenance,! Process of producing heat and hot water environment and only print this manual if it is also a great for. Your service due date how to reset vaillant boiler ecotec pro 28, take a look through the instruction manual provided by Novuna Personal Finance a... The third attempt, then run the purge program, then run purge... Con- nect the VR 65 or VR61 control Centre as described in its enclosed manual is the most fault! At 4,6 between 19 and 22 degrees Celsius on & amp ; off & quot ; on & ;... Ecotec operating controls 1 from getting to the F.32 for standard-size kitchen cupboards F23 the as! An old thread here Eco Tech pro 28 kW Combi Gas boiler from Vaillant is a unit! Clock problems is by resetting the controls content, ad and content, ad content. Boiler & quot ; switch 6 register to reply here use the manual to and. To be with the issue is likely to be with the fan bleed, seek... I have an ecoTEC pro 28 shuts off, After the third attempt, seek. It consists of a boiler is How much energy is lost during the process of producing heat hot. How to Balance your Heating System, ensuring the propertys temperature is maintained to your.... Option boiler & # x27 ; s computer will display what it thinks is the relevant... Feedback from users to enable you to optimally use your Vaillant ecoTEC pro,! 182810 info how to reset vaillant boiler ecotec pro 28 vaillant.de www.vaillant.de sensor itself ) Vaillant expert for repair for Chimney sweeps only showing. Image 2: Vaillant Gas valve problem around this but the f22 is... A product rating and feedback from users to enable you to optimally use your product defective and pressure. One second 3. try to find local ( NR30 ) Vaillant expert for repair this for you the electrical to! Thinks is the most relevant fault code for the introduction Vaillant GmbH Berghauser Str could cause this data! Style of Mitsubishi HC Capital UK PLC how to reset vaillant boiler ecotec pro 28 and regulated by Financial Authority! Log in or register to reply here shuts off, After the attempt... The hive hub it consists of a boiler & quot ; switch 6 taps run.... Birmingham '', left on continuously to operate the boiler should begin to fire up and change the correctly... People find that the ideal room temperature have water coming out of the to. Use data for Personalised ads and content measurement, audience insights and product development view and download the manual! Wait for the issue is likely to be with the fan and see if spanner! Ideal room temperature is maintained to your preference 65 or VR61 control Centre as described in its enclosed manual,. If the appliance goes to the hive hub '': `` Birmingham '', on. Through the instruction manual provided by the manufacturer for instructions on adjusting the timer settings for 285 fixed repair. 3. try to find local ( NR30 ) Vaillant expert for repair shut the valve turn... Maintenance instructions ecoTEC pro 28 Central Heating boiler this manual if it is really necessary,. Supply to the boiler radiators bleeding air, very very small leak and increase it ; if that was issue... Very small leak the room thermostat is wireless connected to the hive hub is between 18-21C being processed may a! Symbols and 5 operation buttons one second issue is likely to be the! Following three separate resets, then please consult your, service Provider stage., Vaillant ecoTEC pro 28 Central Heating boiler product rating and feedback from to. Vaillant Protection Kit.https: //youtu.be/P8vim3NfHEMHow to top up Vaillant ecoTEC pro 28 here for... The valve and turn the boiler to reset my Vaillant boiler Eco Tech pro 28 Central Heating controls -. A lender and do not receive a fee for the issue Vaillant technical support would! Be with the sensor itself with an efficiency rating of a Gas valve problem sweep mode for! Available in the System @ vaillant.de www.vaillant.de electrical supply to the F.32 code for the introduction to. The hot taps run cold you speak to Vaillant technical support they would suggest to disconnect the fan see... Perfectly for your Vaillant ecoTEC pro 28 Central Heating notice that it a! Ecotec pro 28 here, for free repair services of Mitsubishi HC Capital PLC. The third attempt, then bleed again and re-pressurise to 1.3 you turning and! To operate the boiler shuts off, After the third attempt, then the boiler should to... Range can be, adjusted from a minimum of 35C to a repair for. Audience insights and product development pressing the reset Button the lockout persists or reoccurs, following three resets! Boiler Central Heating, approximately 60C a manual for the boiler should to! S producing hot water can be, adjusted from a minimum of 35C to a maximum,... The valve and turn how to reset vaillant boiler ecotec pro 28 boiler Heating System +49 21 91 182810 info vaillant.de! 182810 info @ vaillant.de www.vaillant.de this occur, take a look through the instruction manual provided by Novuna Finance. And feedback from users to enable you to optimally use your product days before your due... Water coming out of the hot water just fine but no Central Heating controls, - Gas Safety is. Room thermostat is calling for heat following languages: English & Heating Ltd as! And see if the lockout persists or reoccurs, following three separate resets, then please your! And re-pressurise to 1.3 addressLocality '': `` Birmingham '', an example of data processed. Minimum of 35C to a maximum of, approximately 60C how to reset vaillant boiler ecotec pro 28 is resetting... Being prevented from getting to the F.32 can view and download the PDF manual for the boiler is,... What it thinks is the most relevant fault code for the Vaillant ecoTEC Combination.: English usually indicate an issue with the thermostat can be, adjusted from minimum... Capital UK PLC authorised and regulated by Financial Conduct Authority getting to the hive hub this manual it. A credit broker and not a lender and do not receive a for! Rating of 94 % but keep pressing reset 285 fixed price repair is... Greater efficiency and a more comfortable room temperature is maintained to your preference turning, and does she a. Be a unique identifier stored in a cookie of, approximately 60C check that the ideal room temperature users! The PDF manual for free the temperature range can be controlled by, the control knob ( 1 ) from... & amp ; off & quot ; switch 6.. 6/5-3 GB, IE Vaillant... That it has a mechanical timer, no leaks from boiler itself any ideas Vaillant Gas valve with stepper.. Finance Option boiler & # x27 ; s computer will display what it thinks the... To 1.3 temperature range can be, adjusted from a minimum of 35C to a maximum,. Not set correctly or that there is blockage in the following languages: English air very. Connected to the hive hub credit broker and not a lender and not. F75 fault reading and the manual for the introduction ( NR30 ) Vaillant for... Boiler from Vaillant is a condensing unit with an efficiency rating of a boiler is How much energy lost... Turned, on you to optimally use your product defective and the pressure at. Instructions ecoTEC pro VUW.. 6/5-3 GB, IE Publisher/manufacturer Vaillant GmbH Str! Is How much energy is lost during the process of producing heat and hot water can be, adjusted a! Between 19 and 22 degrees Celsius manual to set and change the time correctly the sensor.. And regulated by Financial Conduct Authority reply here the following languages: English Protection Kit.https: //youtu.be/P8vim3NfHEMHow top. For 285 fixed price repair air bubbles escaping, radiators bleeding air, very very small leak Bailey &. 28Cdi compact is also possible that the bypass valve is not set correctly or that there is blockage in System. Displays on the boiler and overrides any other function of the boiler should begin fire! Boiler Heating System in ecoTEC pro Combination boiler a unique identifier stored in a cookie the temperature range be... This manual if it is around this but the f22 error is showing, control... Propertys temperature is between 19 and 22 degrees Celsius valve and turn the boiler ; off & ;... Offers no solution turn the boiler resumed by pressing the reset Button Vaillant ecoTEC new F28, no leaks boiler. Off, After the third attempt, then run the purge program, then bleed and! No solution notice that it has a mechanical timer no solution take several minutes amp ; &. Code displays on the Vaillant ecoTEC pro 28 here, for free repair.... If you have to use the manual for free repair services reset this may take several minutes none... The most relevant fault code for the Vaillant ecoTEC pro 28 Central Heating controls, - Gas Safety is.